Utilizziamo i cookie per rendere migliore la tua esperienza di navigazione. Per rispettare la nuova direttiva sulla privacy, è necessario chiedere il tuo consenso per impostare i cookie. Per saperne di più.
IXXAT INpact allows you to connect a PC to any industrial network. It combines proven Anybus technology with years of IXXAT know-how in the area of PC interfaces. The Common Ethernet variant provides a common platform for various industrial Ethernet protocols, like PROFINET, EtherNet/IP, Modbus-TCP, EtherCAT and Powerlink. The communication software for the selected network can easiely be downloaded to the interface.
- Two Ethernet ports with Ethernet RJ45 connectors
- 10/100 Mbit, full/half duplex operation
- Web server with customizable content
- FTP server
- E-mail client
- JSON functionality
- Server Side Include (SSI) functionality
- Transparent Socket Interface
More information about the special features for PROFINET, EtherNet/IP, Modbus-TCP,
EtherCAT and Powerlink can be found on the protocol specific INpact pages...
Getting Started Support
We offer our customers support via phone, e-mail and Teamviewer in getting started the quickest way possible. This includes assistance in installation of the INpact PC card and driver, explaining the included programming examples, and giving an introduction to process data mapping and PLC configuration.
Additional Support
Extended support such as mapping process data, detailed introduction to the sample code, etc. can be offered on an hourly base as general technical service.
Multi-Protocol approach
The IXXAT INpact Common Ethernet enables easy connection of PC based slave applications to various industrial Ethernet networks, such as
- PROFINET
- EtherNet/IP
- EtherCAT
- Powerlink
- Modbus TCP
The software for the various protocols can easily be downloaded to the interface. This highly flexible approach allows easy switching between all available protocols in a quick and cost-efficient manner without any additional costs.
The multi-network capability of INpact is based on HMS’ proven Anybus CompactCom technology used within millions of automation devices globally. The network connection is made through a 2-port Ethernet interface (10/100 Mbit, RJ45), which also supports protocol specific switch functions – such as IRT for PROFINET, DLR for EtherNet/IP and Hub for Powerlink.
The efficient FPGA-based Anybus NP40 network processor handles the communication, providing all functions required to process the communication between the different Industrial Ethernet networks and the PC-based application.
Easy and protocol independent programming
The INpact cards comes with a comprehensive C-API based driver package for Windows – enabling simple and rapid development of customer-specific applications – and with drivers for Linux. Thanks to the uniform application programming interface, it is possible to switch quickly between industrial Ethernet protocols without extensive programming, which leads to increased flexibility and a reduction in terms of development costs.
Operating systems such as RTX, Intime, VxWorks and QNX are supported upon request.
INpact CE Slave PCIe Standard/Low Profile | INpact CE Slave PCIe Mini | INpact CE Slave M.2 | |
Field bus interface | Two Ethernet ports, 100/10 Mbit | Two Ethernet ports, 100/10 Mbit | Two Ethernet ports, 100/10 Mbit |
PC interfaces | PCI Express single lane port (x1) according to PCI Express base specification, revision 1.1 | PCI Express single lane port (x1) | PCI Express single lane port (x1) |
Network handling | Anybus NP40 | Anybus NP40 | Anybus NP40 |
Power supply | Via PCIe socket (3.3 V / 12 V DC) | Via PCIe (3.3 V) | Via PCIe (3.3 V) |
Current consumption | Typ. 270 mA / 3.3 V DC, 110 mA / 12 V DC | Typ. 600 mA / 3.3 V DC | Typ. 600 mA / 3.3 V DC |
Form factor | Standard height / low profile PCI Express add-in card profile | Full Mini Card form factor | M.2 2260 (Key B-M) |
Operating temperature range | 0 °C to 70 °C Option: -40 °C to 70° C | -40 °C to 60 °C | -20 °C to 60 °C |
Galvanic isolation | 1,500 Vrms | 1,500 Vrms | 1,500 Vrms |
Dimensions | 64 x 105 mm | 30 x 50.95 x 12 mm (with cable) | 22 x 60 x 12 mm (with cable) |
Weight | approx. 53 g | approx. 48 g (only interface with connected cable) | approx. 25 g (only interface with connected cable) |
Certification | CE, FCC | CE, FCC | CE, FCC |
- One board for all common industrial Ethernet networks
- Easy switching between protocols through a standardized API
- Fast time to market, with minimal development efforts required
- Easy integration thanks to different form factors
- High performance for demanding real-time applications
- Future-proof solution based on proved IXXAT and Anybus technologies
Product name | Supported protocol | Order number |
INpact CE Slave PCIe Standard Profile | Common Ethernet | 1.01.0320.20110 |
INpact CE Slave PCIe Low Profile | Common Ethernet | 1.01.0320.20120 |
INpact CE Slave PCIe Mini with connection cable (150 mm), bus coupling unit and mini bracket | Common Ethernet | 1.01.0340.20151 |
INpact CE Slave M.2 with connection cable (150 mm), bus coupling unit and mini bracket | Common Ethernet | on request |
Connection cable (300 mm) for INpact PCIe Mini or M.2 | 1.04.0340.00001 |